Gamatronic’s Power+ Rack Mount 10-100kVA UPS system is the complete, optimal solution for server rooms and data centers.  Housed in 19″ uniform and modern cabinets, the unit integrates perfectly with existing data center design.

Features

Internal electronic static mechanism for supplying users directly from the electrical grid in the event of a malfunction. This feature enables the UPS to maintain a continuous supply of electricity to users in all scenarios. Battery wiring system does not require an input or output transformer External battery cabinet The unit is controlled using SNMP (optional) or RS232 Dry contacts for operation with PLC 96% electrical efficiency

Available in the following configurations

Three phase input and single phase output Three phase input and output Single phase input and output
t: (902) 468-6968 tf: (888) 472-3919
Universal Power Solutions Inc.
Universal Power Solutions Inc.
 Download User Manual Download User Manual Download Brochure Download Brochure 10kVA 20kVA 30kVA 40kVA 50kVA 60kVA 70kVA 80kVA 90kVA 100kVA 10/8 20/16 30/24 40/32 50/40 60/48 70/56 80/64 90/72 100/80 10kVA 20kVA 30kVA 40kVA 50kVA 60kVA 70kVA 80kVA 90kVA 100kVA 27.2 31.1 34.6 38.2 4.21 49.6 53.2 56.7 60.6 64.6 223 258 291 326 359 428 463 496 531 654 48 52 53 54 55 55.8 56.4 57 57.5 58 51 54 55 57 58 58.8 59.4 60 60.5 61 Noise (dBA) with Half Load Noise (dBA) with Full Load Sinusoidal 1 Hz / sec Acoustic Noise 23.6 27.2 39 Slew Rate Waveform Width (in) Depth (in) Weight (lbs) Standards IEC62040-2; FCC part 15-B.  14°F to 104°F (operating), -4 to 140°F(storage) 95 % max non-condensing  1500 m without derating  Multi-Fan with speed control (forced)  Cooling system IP20 Enclosure On-line Doube Conversion Modular Redundant with Hybrid Central Static Switch POWER+ Classic SPECIFICATIONS 3 x 208 Three Phase L1, L2, L3, N -25% to +15% of nominal 28 Amps per 10kVA Module, No inrush current at Startup Topology Voltage Model RM100 Capacity (kVA / kW) Input Static Regulation +-1% Regulation - Unbalanced Load +/- 1% for 100% Unbalanced Load Sealed, lead acid, rechargeable  Ambient Temperature Relative Humidity Altitude Height (in) Type UL 1778; IEC62040-1-1 Dimensions Safety EMC Emission UPS General Load Crest Factor (Max) Effiency (Nominal) Type 4:1 AC/AC 94% on-line, DC/AC 97% DC Link Voltage Nominal Quantity Batteries ±160 Vdc to ±216 Vdc  32 × 12 V  THD Output 3 x 208 Three Phase L1, L2, L3, N 60Hz +/- 2Hz < 2% for linear Load Voltage Frequency Tracking Range Dynamic Response +/- 2% (100% Step Load) Overload 110% for 10 min; 125% for 60 sec; 1000% for 1 cycle 5% 0.99 Voltage Range Current Frequency (Hz) Power Walk In Current Distortion (THDI) Input Power Factor 47 - 63Hz > 60 Seconds
Power+ RM100

Power+ RM100

Info & Details

Gamatronic’s Power+ Rack Mount 10-100kVA UPS system is the complete, optimal solution for server rooms and data centers.  Housed in 19″ uniform and modern cabinets, the unit integrates perfectly with existing data center design.

Features

Internal electronic static mechanism for supplying users directly from the electrical grid in the event of a malfunction. This feature enables the UPS to maintain a continuous supply of electricity to users in all scenarios. Battery wiring system does not require an input or output transformer External battery cabinet The unit is controlled using SNMP (optional) or RS232 Dry contacts for operation with PLC 96% electrical efficiency

Available in the following

configurations

Three phase input and single phase output Three phase input and output Single phase input and output
Universal Power Solutions Inc.
Download User Manual Download User Manual Download Brochure Download Brochure
t: (902) 468-6968 tf: (888) 472-3919