Power+ RM50

Power+ RM50

Info & Details

Gamatronic’s Power+ Rack Mount 10-50kVA UPS system is the complete, optimal solution for server rooms and data centers.  Housed in 19″ uniform and modern cabinets, the unit integrates perfectly with existing data center design.

Features

Internal electronic static mechanism for supplying users directly from the electrical grid in the event of a malfunction. This feature enables the UPS to maintain a continuous supply of electricity to users in all scenarios. Battery wiring system does not require an input or output transformer External battery cabinet The unit is controlled using SNMP (optional) or RS232 Dry contacts for operation with PLC 96% electrical efficiency

Available in the following configurations

Three phase input and single phase output Three phase input and output Single phase input and output  
t: (902) 468-6968 tf: (888) 472-3919
Universal Power Solutions Inc.
Universal Power Solutions Inc.
Download User Manual Download User Manual Download Brochure Download Brochure 10kVA 20kVA 30kVA 40kVA 50kVA 10/8 20/16 30/24 40/32 50/40 1243 1265 1287 1786 1808 51 54 55 57 58 UL 1778; IEC62040-1-1 4.5 9 13.5 18 22.5 Input Channels User Interface Acoustic Noise (Full Load) @ 1.5M (dB) Safety EMC Emission Communications Log( events memory) System Operation without Controller Output Contacts On-line Doube Conversion Modular Redundant with Hybrid Central Static Switch 3 x 208 Three Phase L1, L2, L3, N 3 x 208 Three Phase L1, L2, L3, N 27.8 Amps per 10kVA Module Menu driven LCD 4 Digital, 8 Analog 4 Progammable Dry Contacts Continuous with disruption 255 events 384V (+192, -192) Max Charging Current at Full Load DC Link Voltage Nominal Add 200 lbs for pallet and crating 1740 btu/hr per 10kVA power module at full load SNMP / Web Interface, TCP/IP Standard IEC62040-2; FCC part 15-B.  110% for 10 min; 125% for 60 sec; 1000% for 1 cycle < 2% for linear Load 4:1 AC/AC 94% on-line, DC/AC 97% 14°F to 104°F (operating), -4 to 140°F(storage) 22 Power+ Controller Standards Battery/Charger Hybrid Static Switch with Auto Wrap-around Contactor EPO Connection (powered NC) and Load on Bypass (dry contacts NC) 80" x 24" x 39.4" (19" x 42U rack) Ambient Temperature 10kVA/8kW Module Weight (lbs) UPS Dimensions (HxWxD) UPS Weight (lbs) UPS Shipping Weight (lbs) Maximum Heat Disipation Type Static Switch Control Connections UPS General Regulation - Unbalanced Load Dynamic Response Overload THD Load Crest Factor (Max) Effiency (Nominal) Current Frequency Tracking Range Power Walk In Current Distortion (THDI) Input Power Factor Static Regulation 60Hz +/- 2Hz +-1% +/- 1% for 100% Unbalanced Load +/- 2% (100% Step Load) Output 45 - 63Hz > 60 Seconds < 5% at full load 0.99 Voltage Voltage Range Current Frequency (Hz) -25% to +15% @ 80% load +/- 15% @ 100% load 29.6 Amps per 10kVA Module, No inrush current at Startup Topology Input Voltage Model RM50 POWER+ RM50 SPECIFICATIONS Capacity (kVA / kW)
Power+ RM50

Power+ RM50

Info & Details

Gamatronic’s Power+ Rack Mount 10-50kVA UPS system is the complete, optimal solution for server rooms and data centers.  Housed in 19″ uniform and modern cabinets, the unit integrates perfectly with existing data center design.

Features

Internal electronic static mechanism for supplying users directly from the electrical grid in the event of a malfunction. This feature enables the UPS to maintain a continuous supply of electricity to users in all scenarios. Battery wiring system does not require an input or output transformer External battery cabinet The unit is controlled using SNMP (optional) or RS232 Dry contacts for operation with PLC 96% electrical efficiency

Available in the following

configurations

Three phase input and single phase output Three phase input and output Single phase input and output  
Universal Power Solutions Inc.
Download User Manual Download User Manual Download Brochure Download Brochure
t: (902) 468-6968 tf: (888) 472-3919